RG 174/U



Cables are also available with polyisobutylene floodant and HDPE Jacket for direct burial, as well as FT-1 Outdoor versions with a low temperature ultra-violet resistant PVC jacket with or without steel messengers.
Aluminum or Steel Interlock Armour and Jacket available upon request.
Home
Coax Index
Search
Previous       Next
ECI
Catalogue
Number
Description Nominal
O.D.
(inches)
Nominal
Capacitance
pF/ft
Nominal
Impedance
(Ohms)
Nominal %
Velocity of
Propagation
Nominal
Attenuation
MHz dB/100 ft
4092695FT1
RG 174/U 26/7 Copperweld
Solid Polyethylene Dielectric
95% Tinned Copper Braid
PVC Jacket, CSA - UL
Flame Rated FT-1
.110 30.8 50 66 50
100
200
400
6.5
8.8
13.0
20.0

RG 213/U
ECI
Catalogue
Number
Description Nominal
O.D.
(inches)
Nominal
Capacitance
pF/ft
Nominal
Impedance
(Ohms)
Nominal %
Velocity of
Propagation
Nominal
Attenuation
MHz dB/100 ft
4131395FT1
4131395FT4
RG 213/U 13/7 x .0296 SBC
Solid Polyethylene Dielectric
97% Bare Copper Braid
PVC Jacket, CSA - UL
Flame Rated FT-1 or FT-4
.405 30.8 50 66 50
100
400
700
900
1.3
2.0
4.9
6.9
8.0

RG 214/U (Commercial Grade)
ECI
Catalogue
Number
Description Nominal
O.D.
(inches)
Nominal
Capacitance
pF/ft
Nominal
Impedance
(Ohms)
Nominal %
Velocity of
Propagation
Nominal
Attenuation
MHz dB/100 ft
4191495FT1
4191495FT4
RG 214/U 13/7 x .0296 STC
Solid Polyethylene Dielectric
Double 95% Tinned Copper Braid
PVC Jacket, CSA - UL
Flame Rated FT-1 or FT-4
.425 29.5 50 66 50
100
400
700
900
1000
1.6
2.3
5.0
6.9
8.0
9.0

06/02/2000: Rev. 3: cpage 9: coaxial catalog