| Cables are also available with polyisobutylene
floodant and HDPE Jacket for direct burial, as well as FT-1 Outdoor
versions with a low temperature ultra-violet resistant PVC jacket with or
without steel messengers. Aluminum or Steel Interlock Armour and Jacket available upon request. | Home Coax Index Search Previous Next |
| ECI Catalogue Number | Description | Nominal O.D. (inches) | Nominal Capacitance pF/ft | Nominal Impedance (Ohms) | Nominal % Velocity of Propagation | Nominal Attenuation | |
|---|---|---|---|---|---|---|---|
| MHz | dB/100 ft | ||||||
| 4702007FT1 4702007FT4 | 2 Conductor 20/7 1 Tinned, 1 Bare Solid Polyethylene Insulation Twisted, Solid Polyethylene Insulation, 100% Aluminum, Polyester, Aluminum Shield 86% Tinned Copper Braid PVC Jacket, CSA Flame Rated FT-1 or FT-4 | .330 | 15.5 | 100 | 66 | 1 10 20 50 100 200 400 | 0.4 1.1 1.5 2.5 4.1 6.4 10.2 |
| ECI Catalogue Number | Description | Nominal O.D. (inches) | Nominal Capacitance pF/ft | Nominal Impedance (Ohms) | Nominal % Velocity of Propagation | Nominal Attenuation | |
|---|---|---|---|---|---|---|---|
| MHz | dB/100 ft | ||||||
| 4702063FT1 4702063FT4 | 2 Conductor 20/7 Tinned Copper Solid Polyethylene Insulation Fillers, 100% Foil Shield, 22/7 Tinned Copper Drain Wire, 57% Tinned Copper Braid PVC Jacket, CSA - UL Flame Rated FT-1 or FT-4 | .242 | 19.7 | 78 | 66 | 50 100 200 400 | 5.0 7.5 11.0 16.0 |
06/02/2000: Rev. 3: cpage 12: coaxial catalog