Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

bool(false)
bool(true)
bool(false)
  

Browse Products

  • Is Logged In:
  • Is Admin:
  • Permission:
  • Can View Transit:
You do not have permission to view this page.
Home > Shop > Transit & Railway Cable > Life Safety - NFPA 130 > CIC TC-ER FT4-ST1 > Control Copper Conductors > Unshielded Multi-Conductor 600V > CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 10 AWG Copper Conductor

ElectroControl®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 10 AWG Copper Conductor

CIC 600V CSA FT4-ST1 TC-ER - Un-Shielded 10 AWG Copper Conductor

Temperature Range:

CSA Type XL 90°C dry/wet 600V

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V

Colour Code:

2C Black & White, 3C Black, Red & Blue, 4C Black, Red, Blue & White, 5C - 50C Black with White Numbers

Bonding Conductor:

Green Insulated Stranded Bare Soft Copper, ASTM B8

Jacket:

Thermoplastic Flame Retardant LSZH Compound

  • CIC

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Tray Cable

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables (Type RW90)
  • CSA C22.2 No. 230, Tray Cables Exposed Run (Type TC-ER)
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • NFPA 130 Smoke and Flame requirements.
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, Direct Burial, Low Acid Gas (AG14), Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.

For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).

Cables marked TC-ER tray cable are permitted for exposed runs as per CE Code Part I 12-2202 3) and 4).

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

6XNAUS10-2CG-P4E, 6XNAUS10-3CG-P4E, 6XNAUS10-4CG-P4E, 6XNAUS10-5CG-P4E, 6XNAUS10-6CG-P4E, 6XNAUS10-7CG-P4E, 6XNAUS10-8CG-P4E, 6XNAUS10-9CG-P4E, 6XNAUS10-10CG-P4E, 6XNAUS10-11CG-P4E, 6XNAUS10-12CG-P4E, 6XNAUS10-15CG-P4E, 6XNAUS10-20CG-P4E, 6XNAUS10-25CG-P4E, 6XNAUS10-30CG-P4E, 6XNAUS10-40CG-P4E, 6XNAUS10-50CG-P4E

CONDUCTOR COUNT

2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 20, 25, 30, 40, 50

BONDING CONDUCTOR SIZE

10 AWG

INSULATION THICKNESS

0.030 in. ~ 0.8 mm

JACKET THICKNESS

0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm

CABLE O.D.

0.463 in. ~ 11.8 mm, 0.489 in. ~ 12.4 mm, 0.564 in. ~ 14.3 mm, 0.615 in. ~ 15.6 mm, 0.635 in. ~ 16.1 mm, 0.667 in. ~ 16.9 mm, 0.719 in. ~ 18.3 mm, 0.745 in. ~ 18.9 mm, 0.778 in. ~ 19.8 mm, 0.808 in. ~ 20.5mm, 0.877 in. ~ 22.3 mm, 0.976 in. ~ 24.8 mm, 1.107 in. ~ 28.1 mm, 1.229 in. ~ 31.2 mm, 1.300 in. ~ 33.0 mm, 1.455 in. ~ 37.0 mm, 1.619 in. ~ 41.1 mm

CABLE WEIGHT

148 lbs/Mft ~ 220 kg/km, 191 lbs/Mft ~ 284 kg/km, 253 lbs/Mft ~ 376 kg/km, 304 lbs/Mft ~ 452 kg/km, 348 lbs/Mft ~ 518 kg/km, 393 lbs/Mft ~ 585 kg/km, 441 lbs/Mft ~ 657 kg/km, 486 lbs/Mft ~ 723 kg/km, 532 lbs/Mft ~ 791 kg/km, 577 lbs/Mft ~ 858 kg/km, 656 lbs/Mft ~ 977 kg/km, 797 lbs/Mft ~ 1187 kg/km, 1026 lbs/Mft ~ 1527 kg/km, 1254 lbs/Mft ~ 1866 kg/km, 1473 lbs/Mft ~ 2193 kg/km, 1914 lbs/Mft ~ 2848 kg/km, 2356 lbs/Mft ~ 3506 kg/km

MAX. PULLING TENSION

166 lbs ~ 75 kg, 249 lbs ~ 113 kg, 332 lbs ~ 151 kg, 415 lbs ~ 188 kg, 498 lbs ~ 226 kg, 581 lbs ~ 264 kg, 664 lbs ~ 301 kg, 747 lbs ~ 339 kg, 830 lbs ~ 377 kg, 913 lbs ~ 283 kg, 996 lbs ~ 452 kg, 1245 lbs ~ 565 kg, 1660 lbs ~ 753 kg, 2075 lbs ~ 941 kg, 2490 lbs ~ 1130 kg, 3320 lbs ~ 1506 kg, 4150 lbs ~ 1883 kg

MIN. BEND RADIUS

4.2 in. ~ 106 mm, 4.4 in. ~ 112 mm, 5.1 in. ~ 129 mm, 5.5 in. ~ 141 mm, 5.7 in. ~ 145 mm, 6.0 in. ~ 152 mm, 6.5 in. ~ 164 mm, 6.7 in. ~ 170 mm, 7.0 in. ~ 178 mm, 7.3 in. ~ 185 mm, 7.9 in. ~ 200 mm, 8.8 in. ~ 223 mm, 10.0 in. ~ 253 mm, 11.1 in. ~ 281 mm, 11.7 in. ~ 297 mm, 13.1 in. ~ 333 mm, 14.6 in. ~ 370 mm

AMPACITY (A)

40, 40, 32, 32, 32, 28, 28, 28, 28, 28, 28, 28, 28, 24, 24, 24, 20

Related products

  • CIC 600V CSA FT4-ST1 TC-ER - Un-Shielded 12 AWG Copper Conductor

    CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 12 AWG Copper Conductor

    $0.00
    Select options
  • CIC 600V CSA FT4-ST1 TC-ER - Un-Shielded 14 AWG Copper Conductor

    CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 14 AWG Copper Conductor

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2025 ELECTRO CABLES • SITE BY SNAP 360•