Home > Shop > Transit & Railway Cable > Life Safety - NFPA 130 > ACIC FT4-ST1 > ACIC SHIELDED PAIRS & TRIADS > ACIC 600V CSA FT4-ST1 – Shielded 16 AWG Tinned Copper Conductor

ElectroSignal®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

ACIC 600V CSA FT4-ST1 – Shielded 16 AWG Tinned Copper Conductor

ACIC 600V CSA FT4-ST1 - Shielded 16 AWG Tinned Copper Conductor

Conductor:

Stranded Tinned Soft Copper, ASTM B8, B33

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 105°C dry, 90°C wet 6zwfq00V, Halogen-Free

Shield:

Individual and Overall Shield with Tinned Copper Drain Wires

Inner Jacket:

Thermoplastic Flame Retardant LSZH Compound

Armour:

Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour

Outer Jacket:

Thermoplastic Flame Retardant LSZH Compound

  • ACIC

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • Halogen
    Free

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 239, Control and instrumentation cables (Type ACIC)
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
  • CSA C22.2 No. 174, Cables and Cable Glands for use in Hazardous Locations (HL-ABCD)
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • NFPA 130 and NFPA 502, Smoke and Flame requirements.
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, Direct Burial, Low Acid Gas (AG14), Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.

Approved for all Hazardous Locations (HL-ABCD) as per CE Code Part I 2024 Section 18, when installed with approved connectors.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

6XAAOS16-1PR, 6XAAISOS16-2PR, 6XAAISOS16-4PR, 6XAAISOS16-6PR, 6XAAISOS16-8PR, 6XAAISOS16-12PR, 6XAAOS16-1TR, 6XAAISOS16-2TR, 6XAAISOS16-4TR, 6XAAISOS16-6TR, 6XAAISOS16-8TR, 6XAAUS16-4C-NH, 6XAAUS16-6C-NH, 6XAAUS16-12C-NH, 6XAAUS16-20C-NH, 6XAAUS16-50C-NH

CONDUCTOR COUNT

1 PAIR, 2 PAIR, 4 PAIR, 6 PAIR, 8 PAIR, 12 PAIR, 1 TRIAD, 2 TRIAD, 4 TRIAD, 6 TRIAD, 8 TRIAD, 4, 6, 12, 20, 50

INSULATION THICKNESS

0.030 in. ~ 0.76mm

INNER JACKET O.D.

0.329 in. ~ 8.36 mm, 0.568 in. ~ 14.44 mm, 0.665 in. ~ 16.89 mm, 0.804 in. ~ 20.41 mm, 0.874 in. ~ 22.20 mm, 1.074 in. ~ 27.28 mm, 0.347 in. ~ 8.81 mm, 0.604 in. ~ 15.33 mm, 0.707 in. ~ 17.97 mm, 0.857 in. ~ 21.76 mm, 0.932 in. ~ 23.68 mm

ARMOUR O.D.

0.549 in. ~ 13.95 mm, 0.788 in. ~ 20.03 mm, 0.885 in. ~ 22.47 mm, 1.024 in. ~ 26.00 mm, 1.094 in. ~ 27.79 mm, 1.329 in. ~ 33.76 mm, 0.567 in. ~ 14.40 mm, 0.824 in. ~ 20.92 mm, 0.927 in. ~ 23.55 mm, 1.077 in. ~ 27.34 mm, 1.152 in. ~ 29.27 mm

CABLE O.D.

0.669 in. ~ 17.0 mm, 0.948 in. ~ 24.09 mm, 1.045 in. ~ 26.54 mm, 1.184 in. ~ 30.06 mm, 1.254 in. ~ 31.86 mm, 1.489 in. ~ 37.82 mm, 0.687 in. ~ 17.45 mm, 0.984 in. ~ 24.99 mm, 1.087 in. ~ 27.62 mm, 1.237 in. ~ 31.41 mm, 1.312 in. ~ 33.33 mm

CABLE WEIGHT

173 lbs/Mft ~ 258 kg/km, 327 lbs/Mft ~ 486 kg/km, 416 lbs/Mft ~ 620 kg/km, 523 lbs/Mft ~ 778 kg/km, 602 lbs/Mft ~ 897 kg/km, 794 lbs/Mft ~ 1182 kg/km, 193 lbs/Mft ~ 287 kg/km, 366 lbs/Mft ~ 545 kg/km, 485 lbs/Mft ~ 722 kg/km, 622 lbs/Mft ~ 925 kg/km, 730 lbs/Mft ~ 1086 kg/km

MAX. PULLING TENSION

41 lb ~ 19 kg, 83 lb ~ 37 kg, 165 lb ~ 75 kg, 248 lb ~ 112 kg, 330 lb ~ 150 kg, 495 lb ~ 225 kg, 62 lb ~ 28 kg, 495 lb ~ 225 kg, 83 lb ~ 37 kg, 124 lb ~ 56 kg, 248 lb ~ 112 kg, 413 lb ~ 187 kg, 1032 lb ~ 468 kg, 372 lb ~ 169 kg

MIN. BEND RADIUS

9 in. ~ 225 mm, 11 in. ~ 292 mm, 13 in. ~ 331 mm, 14 in. ~ 355 mm, 16 in. ~ 416 mm, 18 in. ~ 446 mm, 10 in. ~ 244 mm, 14 in. ~ 350 mm, 15 in. ~ 387 mm, 17 in. ~ 440 mm, 18 in. ~ 467 mm

Related products

  • ACIC 300V CSA FT4-ST1 - Shielded 16 AWG Tinned Copper Conductor

    ACIC 300V CSA FT4-ST1 – Shielded 16 AWG Tinned Copper Conductor

    $0.00
    Select options
  • ACIC 300V CSA FT4-ST1 - Shielded 18 AWG Tinned Copper Conductor

    ACIC 300V CSA FT4-ST1 – Shielded 18 AWG Tinned Copper Conductor

    $0.00
    Select options
  • ACIC 600V CSA FT4-ST1 - Shielded 18 AWG Tinned Copper Conductor

    ACIC 600V CSA FT4-ST1 – Shielded 18 AWG Tinned Copper Conductor

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • Steel Armour

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2025 ELECTRO CABLES • SITE BY SNAP 360•