Home > Shop > Transit & Railway Cable > Life Safety - NFPA 130 > CIC TC-ER FT4-ST1 > Control Copper Conductors > Unshielded Multi-Conductor 600V > CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 12 AWG Copper Conductor

ElectroControl®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 12 AWG Copper Conductor

CIC 600V CSA FT4-ST1 TC-ER - Un-Shielded 12 AWG Copper Conductor

Temperature Range:

• -40°C Cold Bend and -40°C Cold Impact

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V

Colour Code:

2C Black & White, 3C Black, Red & Blue, 4C Black, Red, Blue & White, 5C - 50C Black with White Numbers

Bonding Conductor:

Green Insulated Stranded Bare Soft Copper, ASTM B8

Jacket:

Thermoplastic Flame Retardant LSZH Compound

  • CIC

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Tray Cable

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables (Type RW90)
  • CSA C22.2 No. 230, Tray Cables Exposed Run (Type TC-ER)
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • NFPA 130 Smoke and Flame requirements.
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, Direct Burial, Low Acid Gas (AG14), Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.

For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).

Cables marked TC-ER tray cable are permitted for exposed runs as per CE Code Part I 12-2202 3) and 4).

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

6XNAUS12-2CG-P4E, 6XNAUS12-3CG-P4E, 6XNAUS12-4CG-P4E, 6XNAUS12-5CG-P4E, 6XNAUS12-6CG-P4E, 6XNAUS12-7CG-P4E, 6XNAUS12-8CG-P4E, 6XNAUS12-9CG-P4E, 6XNAUS12-10CG-P4E, 6XNAUS12-11CG-P4E, 6XNAUS12-12CG-P4E, 6XNAUS12-15CG-P4E, 6XNAUS12-20CG-P4E, 6XNAUS12-25CG-P4E, 6XNAUS12-30CG-P4E, 6XNAUS12-40CG-P4E, 6XNAUS12-50CG-P4E

CONDUCTOR COUNT

2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 20, 25, 30, 40, 50

BONDING CONDUCTOR SIZE

12 AWG

INSULATION THICKNESS

0.030 in. ~ 0.8 mm

JACKET THICKNESS

0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm

CABLE O.D.

0.414 in. ~ 10.5 mm, 0.437 in. ~ 11.1 mm, 0.476 in. ~ 12.1 mm, 0.550 in. ~ 14.0 mm, 0.568 in. ~ 14.4 mm, 0.596 in. ~ 15.1 mm, 0.641 in. ~ 16.3 mm, 0.664 in. ~ 16.9 mm, 0.692 in. ~ 17.6 mm, 0.718 in. ~ 18.2 mm, 0.744 in. ~ 18.9 mm, 0.870 in. ~ 22.1 mm, 0.983 in. ~ 25.0 mm, 1.089 in. ~ 27.6 mm, 1.151 in. ~ 27.7 mm, 1.286 in. ~ 32.7 mm, 1.438 in. ~ 36.3 mm

CABLE WEIGHT

108 lbs/Mft ~ 160 kg/km, 137 lbs/Mft ~ 204 kg/km, 168 lbs/Mft ~ 250 kg/km, 218 lbs/Mft ~ 325 kg/km, 248 lbs/Mft ~ 369 kg/km, 279 lbs/Mft ~ 416 kg/km, 313 lbs/Mft ~ 465 kg/km, 343 lbs/Mft ~ 511 kg/km, 375 lbs/Mft ~ 558 kg/km, 406 lbs/Mft ~ 604 kg/km, 437 lbs/Mft ~ 650 kg/km, 565 lbs/Mft ~ 840 kg/km, 722 lbs/Mft ~ 1075 kg/km, 879 lbs/Mft ~ 1308 kg/km, 1028 lbs/Mft ~ 1530 kg/km, 1328 lbs/Mft ~ 1976 kg/km, 1629lbs/Mft ~ 2424 kg/km

MAX. PULLING TENSION

104 lbs ~ 47 kg, 156 lbs ~ 71 kg, 208 lbs ~ 94 kg, 260 lbs ~ 118 kg, 313 lbs ~ 142 kg, 365 lbs ~ 166 kg, 417 lbs ~ 189 kg, 469 lbs ~ 213 kg, 521 lbs ~ 236 kg, 573 lbs ~ 260 kg, 625 lbs ~ 283 kg, 781 lbs ~ 354 kg, 1042 lbs ~ 473 kg, 1302lbs ~ 591 kg, 1563 lbs ~ 709 kg, 2084 lbs ~ 945 kg, 2605 lbs ~ 1182 kg

MIN. BEND RADIUS

3.7 in. ~ 95 mm, 3.9 in. ~ 100 mm, 4.3 in. ~ 103 mm, 4.2 in. ~ 109 mm, 5.0 in. ~ 126 mm, 5.1 in. ~ 130 mm, 5.4 in. ~ 136 mm, 5.8 in. ~ 147 mm, 6,0 in. ~ 152 mm, 6.2 in. ~ 158 mm, 6.5 in. ~ 164 mm, 6.7 in. ~ 170 mm, 7.8 in. ~ 199 mm, 8.8 in. ~ 225 mm, 9.8 in. ~ 249 mm, 10.4 in. ~ 263 mm, 11.6 in. ~ 294 mm, 12.9 in. ~ 326 mm

AMPACITY (A)

30, 30, 24, 24, 24, 21, 21, 21, 21, 21, 21, 21, 21, 18, 18, 18, 15

Related products

  • CIC 600V CSA FT4-ST1 TC-ER - Un-Shielded 10 AWG Copper Conductor

    CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 10 AWG Copper Conductor

    $0.00
    Select options
  • CIC 600V CSA FT4-ST1 TC-ER - Un-Shielded 14 AWG Copper Conductor

    CIC 600V CSA FT4-ST1 TC-ER – Un-Shielded 14 AWG Copper Conductor

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO