Home > Shop > Transit & Railway Cable > Life Safety - NFPA 130 > CIC TC-ER FT4-ST1 > Power Copper Conductors > CIC 1KV > CIC 1000V CSA FT4-ST1 TC-ER – 2 Conductor Copper

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

CIC 1000V CSA FT4-ST1 TC-ER – 2 Conductor Copper

CIC 1000V CSA FT4-ST1 TC-ER - 2 Conductor Copper

Temperature Range:

CSA Type XL 90°C dry/wet 1000V

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 1000V

Colour Code:

Black & White or Black with White printed number

Bonding Conductor:

Green Insulated Stranded Bare Soft Copper, ASTM B8

Jacket:

Thermoplastic Flame Retardant LSZH Compound

  • CIC

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Tray Cable

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables (Type RW90)
  • CSA C22.2 No. 230, Tray Cables Exposed Run (Type TC-ER)
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • NFPA 130 Smoke and Flame requirements.
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, Direct Burial, Low Acid Gas (AG14), Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.

For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).

Cables marked TC-ER tray cable are permitted to transition between cable trays, and utilization equipment or devices as per CEC Part I 12-2202 2) and 3).

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

1XNAUS8-2CG-P4E, 1XNAUS6-2CG-P4E, 1XNAUS4-2CG-P4E, 1XNAUS3-2CG-P4E, 1XNAUS2-2CG-P4E, 1XNAUS1-2CG-P4E, 1XNAUS1/0-2CG-P4E, 1XNAUS2/0-2CG-P4E, 1XNAUS3/0-2CG-P4E, 1XNAUS4/0-2CG-P4E

POWER CONDUCTOR SIZE

8, 6, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250, 300, 350, 400, 500, 600, 750

BONDING CONDUCTOR SIZE

10, 8, 8, 6, 6, 6, 6, 6, 4, 4, 4, 4, 3, 3, 2, 2, 2

INSULATION THICKNESS

0.045 in. ~ 1.14 mm, 0.060 in. ~ 1.52 mm, 0.080 in. ~ 2.03 mm, 0.090 in. ~ 2.28 mm

JACKET THICKNESS

0.060 in. ~ 1.5 mm, 0.080 in. ~ 2.0 mm, 0.110 in. ~ 2.8 mm

CABLE O.D.

0.597 in. ~ 15.2 mm, 0.734 in. ~ 18.6 mm, 0.886 in. ~ 22.5 mm, 0.944 in. ~ 24.0 mm, 1.006 in. ~ 25.6 mm, 1.132 in. ~ 28.8 mm, 1.206 in. ~ 30.6 mm, 1.284 in. ~ 32.6 mm, 1.376 in. ~ 34.9 mm, 1.508 in. ~ 38.3mm, 1.720 in. ~ 43.7 mm, 1.828 in. ~ 46.4 mm, 1.954 in. ~ 49.6 mm, 2.004 in. ~ 50.9 mm, 2.192 in. ~ 55.7 mm, 2.274 in. ~ 57.8 mm, 2.644 in. ~ 67.2 mm

CABLE WEIGHT

260 lbs/Mft ~ 387 kg/km, 378 lbs/Mft ~ 562 kg/km, 538 lbs/Mft ~ 801 kg/km, 647 lbs/Mft ~ 963 kg/km, 751 lbs/Mft ~ 1117 kg/km, 934 lbs/Mft ~ 1390 kg/km, 1109 lbs/Mft ~ 1650 kg/km, 1297 lbs/Mft ~ 1931 kg/km, 1605 lbs/Mft ~ 2389 kg/km, 1924 lbs/Mft ~ 2863 kg/km, 2391 lbs/Mft ~ 3558 kg/km, 2759 lbs/Mft ~ 4107 kg/km, 3178 lbs/Mft ~ 4729 kg/km, 3525 lbs/Mft ~ 5246 kg/km, 4299 lbs/Mft ~ 6398 kg/km, 4993 lbs/Mft ~ 7430 kg/km, 6121 lbs/Mft ~ 9110 kg/km

MAX. PULLING TENSION

303 lbs ~ 138 kg, 419 lbs ~ 191 kg, 668 lbs ~ 303 kg, 842lbs ~ 383 kg, 1063 lbs ~ 483 kg, 1340 lbs ~ 609 kg, 1687 lbs ~ 767 kg, 2130 lbs ~ 968 kg, 2686 lbs ~ 1221 kg, 3384 lbs ~ 1538 kg, 4000 lbs ~ 1818 kg, 4795 lbs ~ 2180 kg, 5605 lbs ~ 2548 kg, 6403 lbs ~ 2910 kg, 7993 lbs ~ 3633 kg, 9604 lbs ~ 4366kg, 12004 lbs ~ 5456 kg

MIN. BEND RADIUS

5.4 in. ~ 136 mm, 6.6 in. ~ 168 mm, 8.0 in. ~ 202 mm, 8.5 in. ~ 216 mm, 9.1 in. ~ 230 mm, 10.2 in. ~ 259 mm, 10.9 in. ~ 276 mm, 11.6 in. ~ 293 mm, 12.4 in. ~ 314 mm, 13.6 in. ~ 345 mm, 15.5 in. ~ 393 mm, 16.5 in. ~ 418 mm, 17.6 in. ~ 447 mm, 18.0 in. ~ 458 mm, 19.7 in. ~ 501 mm, 20.5 in. ~ 520 mm, 23.8 in. ~ 605 mm

AMPACITY (A)

55, 75, 95, 115, 130, 145, 170, 195, 225, 260, 290, 320, 350, 380, 430, 475, 535

Related products

  • CIC 1000V CSA FT4-ST1 TC-ER - 4 Conductor Copper

    CIC 1000V CSA FT4-ST1 TC-ER – 4 Conductor Copper

    $0.00
    Select options
  • CIC 1000V CSA FT4-ST1 TC-ER - 3 Conductor Copper

    CIC 1000V CSA FT4-ST1 TC-ER – 3 Conductor Copper

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2025 ELECTRO CABLES • SITE BY SNAP 360•