ElectroControl®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

CIC 600V CSA FT4-ST1 TC-ER – Shielded 14 AWG Copper Conductor

CIC 600V CSA FT4-ST1 TC-ER - Shielded 14 AWG Copper Conductor

Temperature Range:

• -40°C Cold Bend and -40°C Cold Impact

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V

Colour Code:

2C Black & White, 3C Black, Red & Blue, 4C Black, Red, Blue & White, 5C - 50C Black with White Numbers

Shield:

Overall Aluminum Mylar Shield with Tinned Copper Drain Wire

Jacket:

Thermoplastic Flame Retardant LSZH Compound

  • CIC

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Tray Cable

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 239, Control and instrumentation cables (Type CIC)
  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables (Type RW90)
  • CSA C22.2 No. 230, Tray Cables Exposed Run (Type TC-ER)
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • NFPA 130 Smoke and Flame requirements.
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, Direct Burial, Low Acid Gas (AG14), Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.

For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).

Cables marked TC-ER tray cable are permitted for exposed runs as per CE Code Part I 12-2202 3) and 4).

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

6XNAOS14-2C-P4E, 6XNAOS14-3C-P4E, 6XNAOS14-4C-P4E, 6XNOS14-5C-P4E, 6XNAOS14-6C-P4E, 6XNAOS14-7C-P4E, 6XNAOS14-8C-P4E, 6XNAOS14-9C-P4E, 6XNAOS14-10C-P4E, 6XNAOS14-11C-P4E, 6XNAOS14-12C-P4E, 6XNAOS14-15C-P4E, 6XNAOS14-20C-P4E, 6XNAOS14-25C-P4E, 6XNAOS14-30C-P4E, 6XNAOS14-40C-P4E, 6XNAOS14-50C-P4E

CONDUCTOR COUNT

2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 20, 25, 30, 40, 50

INSULATION THICKNESS

0.030 in. ~ 0.8 mm

JACKET THICKNESS

0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm

CABLE O.D.

0.361 in. ~ 9.2 mm, 0.381 in. ~ 9.7 mm, 0.415 in. ~ 10.5 mm, 0.454 in. ~ 11.5 mm, 0.469 in. ~ 11.9 mm, 0.495 in. ~ 12.6 mm, 0.565 in. ~ 14.3 mm, 0.585 in. ~ 14.8 mm, 0.610 in. ~ 15.5 mm, 0.632 in. ~ 16.1 mm, 0.655 in. ~ 16.6 mm, 0.730 in. ~ 18.5 mm, 0.869 in. ~ 22.1 mm, 0.961 in. ~ 24.4 mm, 1.015 in. ~ 25.8 mm, 1.133in. ~ 28.8 mm, 1.257 in. ~ 31.9 mm

CABLE WEIGHT

70 lbs/Mft ~ 105 kg/km, 91 lbs/Mft ~ 135 kg/km, 112 lbs/Mft ~ 167 kg/km, 136 lbs/Mft ~ 203 kg/km, 157 lbs/Mft ~ 233 kg/km, 179 lbs/Mft ~ 266 kg/km, 218 lbs/Mft ~ 324 kg/km, 239 lbs/Mft ~ 356 kg/km, 261 lbs/Mft ~ 389 kg/km, 283 lbs/Mft ~ 421 kg/km, 304 lbs/Mft ~ 453 kg/km, 370 lbs/Mft ~ 551 kg/km, 511 lbs/Mft ~ 760 kg/km, 620 lbs/Mft ~ 923 kg/km, 723 lbs/Mft ~ 1076 kg/km, 930 lbs/Mft ~ 1385 kg/km, 1695 lbs/Mft ~ 1708 kg/km

MAX. PULLING TENSION

68 lbs ~ 31 kg, 102 lbs ~ 46 kg, 137 lbs ~ 62 kg, 171 lbs ~ 77 kg, 205 lbs ~ 93 kg, 239 lbs ~ 108 kg, 273 lbs ~ 124 kg, 307 lbs ~ 139 kg, 342 lbs ~ 155 kg, 376 lbs ~ 170 kg, 410 lbs ~ 186 kg, 444 lbs ~ 201 kg, 547 lbs ~ 248 kg, 717 lbs ~ 325 kg, 888 lbs ~ 403 kg, 1059 lbs ~ 480 kg, 1401 lbs ~ 635 kg, 1742 lbs ~ 790 kg

MIN. BEND RADIUS

3.2 in. ~ 83 mm, 3.4 in. ~ 87 mm, 3.7 in. ~ 95 mm, 4.1 in. ~ 104 mm, 4.2 in. ~ 107 mm, 4.5 in. ~ 113 mm, 5.1 in. ~ 129 mm, 5.3 in. ~ 134 mm, 5.5 in. ~ 139 mm, 5.7 in. ~ 144 mm, 5.9 in. ~ 150 mm, 6.6 in. ~ 167 mm, 7.8 in. ~ 199 mm, 8.6 in. ~ 220 mm, 9.1 in. ~ 232 mm, 10.2 in. ~ 259 mm, 11.3 in. ~ 287 mm

AMPACITY (A)

25, 25, 20, 20, 20, 17, 17, 17, 17, 17, 17, 17, 17, 15, 15, 15, 12

Related products

  • CIC 600V CSA FT4-ST1 TC-ER - Shielded 12 AWG Copper Conductor

    CIC 600V CSA FT4-ST1 TC-ER – Shielded 12 AWG Copper Conductor

    $0.00
    Select options
  • CIC 600V CSA FT4-ST1 TC-ER - Shielded 10 AWG Copper Conductor

    CIC 600V CSA FT4-ST1 TC-ER – Shielded 10 AWG Copper Conductor

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2025 ELECTRO CABLES • SITE BY SNAP 360•