Home > Shop > Transit & Railway Cable > Life Safety - NFPA 130 > RW90 TC FT4-ST1 > RW90 TC 1KV FT4-ST1 > RW90 1000V CSA FT4-ST1 TC – 1 Copper Conductor No Jacket

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

RW90 1000V CSA FT4-ST1 TC – 1 Copper Conductor No Jacket

RW90 1000V CSA FT4-ST1 TC - 1 Copper Conductor No Jacket

Conductor:

Stranded Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 1000V, Halogen-Free

  • RW90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Tray Cable

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 38, Thermoset-insulated wires and cables (Type RW90)
  • CSA C22.2 No. 230, Tray Cables (Type TC)
  • CSA C22.2 No. 2556 FT4-ST1, CSA C22.2 No. 2556 FT4, UL 1685 Vertical-Tray Flame Test
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • NFPA 130 Smoke and Flame requirements
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES all colours, Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations and in ceiling air-handling plenums.

For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18)

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

81208FT4, 81206FT4, 81204FT4, 81203FT4, 81202FT4, 81201FT4, 81201/0FT4, 81202/0FT4, 81203/0FT4, 81204/0FT4, 812250FT4, 812350FT4, 812500FT4, 812600FT4, 812750FT4, 8121000FT4

CONDUCTOR SIZE

14/7 AWG, 12/7 AWG, 10/7 AWG, 8 AWG, 6 AWG, 4 AWG, 3 AWG, 2 AWG, 1 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 350 kcmil, 500 kcmil, 600 kcmil, 750 kcmil, 1000 kcmil, 14/1 AWG, 12/1 AWG, 10/1 AWG

CABLE O.D.

0.154 in. ~ 3.91 mm, 0.171 in. ~ 4.34 mm, 0.192 in. ~ 4.88 mm, 0.163 in. ~ 4.14 mm, 0.181 in. ~ 4.60 mm, 0.204 in. ~ 5.18 mm, 0.224 in. ~ 5.69 mm, 0.290 in. ~ 7.37 mm, 0.335 in. ~ 8.51 mm, 0.365 in. ~ 9.27 mm, 0.400 in. ~ 10.16 mm, 0.460 in. ~ 11.68 mm, 0.501 in. ~ 12.73 mm, 0.545 in. ~ 13.84 mm, 0.582 in. ~ 14.78 mm, 0.646 in. ~ 16.41 mm, 0.720 in. ~ 18.29 mm, 0.857 in. ~ 21.77 mm, 0.951 in. ~ 24.16 mm, 1.050 in. ~ 26.67 mm, 1.139 in. ~ 28.93 mm, 1.285 in. ~ 32.64 mm

CABLE WEIGHT

18 lbs/Mft ~ 27 kg/km, 26 lbs/Mft ~ 39 kg/km, 40 lbs/Mft ~ 60 kg/km, 20 lbs/Mft ~ 30 kg/km, 28 lbs/Mft ~ 42 kg/km, 42 lbs/Mft ~ 63 kg/km, 71 lbs/Mft ~ 106 kg/km, 102 lbs/Mft ~ 151 kg/km, 154 lbs/Mft ~ 230 kg/km, 191 lbs/Mft ~ 284 kg/km, 237 lbs/Mft ~ 346 kg/km, 310 lbs/Mft ~ 439 kg/km, 383 lbs/Mft ~ 521 kg/km, 484 lbs/Mft ~ 651 kg/km, 591 lbs/Mft ~ 809 kg/km, 738 lbs/Mft ~ 1006 kg/km, 899 lbs/Mft ~ 1250 kg/km, 1241 lbs/Mft ~ 1631 kg/km, 1748 lbs/Mft ~ 2459 kg/km, 2088 lbs/Mft ~ 3100 kg/km, 2594 lbs/Mft ~ 3608 kg/km, 3432 lbs/Mft ~ 4721 kg/km

MAX. PULLING TENSION

34 lbs ~ 15 kg, 52 lbs ~ 24 kg, 83 lbs ~ 38 kg, 151 lbs ~ 69 kg, 210 lbs ~ 95 kg, 334 lbs ~ 151 kg, 421 lbs ~ 191 kg, 531 lbs ~ 241 kg, 670 lbs ~ 304 kg, 844 lbs ~ 383 kg, 1065 lbs ~ 483 kg, 1343 lbs ~ 609 kg, 1692 lbs ~ 767 kg, 2000 lbs ~ 907 kg, 2802 lbs ~ 1271 kg, 3997 lbs ~ 1813 kg, 4802 lbs ~ 2178 kg, 6002 lbs ~ 2722 kg, 7995 lbs ~ 3627 kg, 34 lbs ~ 15 kg, 52 lbs ~ 24 kg, 83 lbs ~ 38 kg

AMPACITY (A)

25, 30, 40, 55, 75, 95, 115, 130, 145, 170, 195, 225, 260, 290, 380, 430, 475, 535, 615, 350

NOTE: Ampacity values based on CE Code Part I 2021, Table 2. Correction factors may apply.

Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • Exposed
    Run

  • DIRECT
    BURIAL

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2025 ELECTRO CABLES • SITE BY SNAP 360•