RW90 600V CSA FT4-ST1 TC-ER – 14 AWG Copper Conductors

RW90 600V CSA FT4-ST1 TC-ER - 14 AWG Copper Conductors

Temperature Range:

• -40°C Cold Bend and -40°C Cold Impact

Conductor:

Stranded Soft Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) CSA Type XL 105°C dry, 90°C wet 600V, Halogen-Free

Colour Code:

2C Black & White, 3C Black, Red & Blue, 4C Black, Red, Blue & White, 5C - 50C Black with White Numbers

Bonding Conductor:

Stranded Soft Copper, ASTM B8, XLPE Insulated (Green)

Jacket:

Thermoplastic Flame Retardant LSZH Compound

  • RW90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • Limited
    SMOKE

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Tray Cable

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables Type (RW90)
  • CSA C22.2 No. 230, Tray Cables Exposed Run (Type TC-ER)
  • CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test
  • IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test rated
  • NFPA 130 Smoke and Flame requirements.
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, Direct Burial, Low Acid Gas (AG14), Halogen-Free

Applications:

For use in raceways, ventilated, non-ventilated and ladder-type cable trays.

For dry, damp or wet locations, in ceiling air-handling plenums, direct burial, exposed and concealed wiring.

For use in Hazardous locations: Zone 0 (intrinsically safe cables only), Zone 2, Zone 22 (per Section 18).

Cables marked TC-ER tray cable are permitted for exposed runs as per CE Code Part I 12-2202 3) and 4).

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

8201402BBG-P4E, 8201403BBG-P4E, 8201404BBG-P4E, 8201405BBG-P4E, 8201406BBG-P4E, 8201407BBG-P4E, 8201408BBG-P4E, 8201409BBG-P4E, 8201410BBG-P4E, 8201411BBG-P4E, 8201412BBG-P4E, 8201415BBG-P4E, 8201420BBG-P4E, 8201425BBG-P4E, 8201430BBG-P4E, 8201440BBG-P4E, 8201450BBG-P4E

CONDUCTOR COUNT

2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 20, 25, 30, 40, 50

BONDING CONDUCTOR SIZE

14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG

INSULATION THICKNESS

0.030 in. ~ 0.8 mm

JACKET THICKNESS

0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.045 in. ~ 1.1 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.060 in. ~ 1.5 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm, 0.080 in. ~ 2.0 mm

CABLE O.D.

0.372 in. ~ 9.5 mm, 0.392 in. ~ 10.0 mm, 0.427 in. ~ 10.8 mm, 0.465 in. ~ 11.8 mm, 0.481 in. ~ 12.2 mm, 0.504 in. ~ 12.8 mm, 0.574 in. ~ 14.6 mm, 0.594 in. ~ 15.1 mm, 0.619 in. ~ 15.7 mm, 0.641 in. ~ 16.3 mm, 0.664 in. ~ 16.9 mm, 0.739 in. ~ 18.8 mm, 0.878 in. ~ 22.3 mm, 0.970 in. ~ 24.7 mm, 1.025 in. ~ 26.0 mm, 1.142in. ~ 29.0mm, 1.266 in. ~ 32.2 mm

CABLE WEIGHT

87 lbs/Mft ~ 129 kg/km, 108 lbs/Mft ~ 160 kg/km, 130 lbs/Mft ~ 193 kg/km, 154 lbs/Mft ~ 230 kg/km, 175 lbs/Mft ~ 261 kg/km, 197 lbs/Mft ~ 293 kg/km, 237 lbs/Mft ~ 352 kg/km, 259 lbs/Mft ~ 385 kg/km, 281 lbs/Mft ~ 418 kg/km, 303 lbs/Mft ~ 451 kg/km, 325 lbs/Mft ~ 484 kg/km, 393 lbs/Mft ~ 585 kg/km, 536 lbs/Mft ~ 798 kg/km, 649 lbs/Mft ~ 965 kg/km, 755 lbs/Mft ~ 1123 kg/km, 968 lbs/Mft ~ 1441 kg/km, 1183 lbs/Mft ~ 1760 kg/km

MAX. PULLING TENSION

68 lbs ~ 31 kg, 102 lbs ~ 46 kg, 137 lbs ~ 62 kg, 171 lbs ~ 77 kg, 205 lbs ~ 93 kg, 239 lbs ~ 108 kg, 273 lbs ~ 124 kg, 307 lbs ~ 139 kg, 342 lbs ~ 155 kg, 376 lbs ~ 170 kg, 410 lbs ~ 186 kg, 512 lbs ~ 232 kg, 683 lbs ~ 310 kg, 854 lbs ~ 387 kg, 1025 lbs ~ 465 kg, 1367 lbs ~ 620 kg, 1708 lbs ~ 775 kg

MIN. BEND RADIUS

3.3 in. ~ 85 mm, 3.5 in. ~ 90 mm, 3.8 in. ~ 98 mm, 4.2 in. ~ 106 mm, 4.3 in. ~ 110 mm, 4.5 in. ~ 115 mm, 5.2 in. ~ 131 mm, 5.3 in. ~ 136 mm, 5.6 in. ~ 142 mm, 5.8 in. ~ 147 mm, 6.0 in. ~ 152 mm, 6.7 in. ~ 169 mm, 7.9 in. ~ 201 mm, 8.7 in. ~ 222 mm, 9.2 in. ~ 234 mm, 10.3 in. ~ 261 mm, 11.4 in. ~ 289 mm

AMPACITY (A)

25, 25, 20, 20, 20, 17, 17, 17, 17, 17, 17, 17, 17, 15, 15, 15, 12

Related products

  • RW90 600V CSA FT4-ST1 TC-ER - 1 Conductor Copper

    RW90 600V CSA FT4-ST1 TC-ER – 1 Conductor Copper

    $0.00
    Select options
  • RW90 600V CSA FT4-ST1 TC-ER - 12 AWG Copper Conductors

    RW90 600V CSA FT4-ST1 TC-ER – 12 AWG Copper Conductors

    $0.00
    Select options
  • RW90 600V CSA FT4-ST1 TC-ER - 10 AWG Copper Conductors

    RW90 600V CSA FT4-ST1 TC-ER – 10 AWG Copper Conductors

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

Lighting Power & Control-Signal Cable

This content is restricted to site members. If you are an existing user, please log in. New users may register … LEARN MORE “Lighting Power & Control-Signal Cable”

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2025 ELECTRO CABLES • SITE BY SNAP 360•