Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > Control & Instrumentation Cable > CIC TC Shielded Pairs & Triads > CIC Tray Cable 300V – Shielded Pairs & Triads 16 AWG

ElectroControl®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

CIC Tray Cable 300V – Shielded Pairs & Triads 16 AWG

Conductor:

Stranded Tinned Soft Copper, ASTM B8, B33

Insulation:

Cross-linked Polyethylene (XLPE)

Shield:

Individual and Overall Shield with Tinned Copper Drain Wires

Jacket:

Low Acid Gas (LAG) Polyvinyl Chloride (PVC)

  • CIC

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Wiring

  • TRAY
    CABLE (TC)

Specifications and Compliance:

  • CSA C22.2 No. 239, Control and instrumentation cables
  • CSA C22.2 No. 230, Tray Cables
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

For wet and dry locations. For use in raceways, including cable trays.

To be used for exposed and concealed wiring or where subjected to the weather.

For Hazardous Locations Class I-Div. 2, Class II-Div. 2 and Class III-Div. 2 as per CEC Part I J18-152, J18-254 and J18-354.

Cables marked TC-ER tray cable are permitted to transition between cable trays, and utilization equipment or devices as per CEC Part I 12-2202 2) and 3).

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

3XNAOS16-1PR, 3XNAISOS16-2PR, 3XNAISOS16-3PR, 3XNAISOS16-4PR, 3XNAISOS16-6PR, 3XNAISOS16-8PR, 3XNAISOS16-12PR, 3XNAISOS16-24PR, 3XNOS16-1TR, 3XNAISOS16-2TR, 3XNAISOS16-4TR, 3XNAISOS16-6TR, 3XNAISOS16-8TR

CONDUCTOR COUNT

1 PAIR, 2 PAIR, 3 PAIR, 4 PAIR, 6 PAIR, 8 PAIR, 12 PAIR, 24 PAIR, 1 TRIAD, 2 TRIAD, 4 TRIAD, 6 TRIAD, 8 TRIAD

INSULATION THICKNESS

0.015 in. ~ 0.38 mm

CABLE DIAMETER

0.305 in. ~ 7.75 mm, 0.558 in. ~ 14.18 mm, 0.591 in. ~ 15.00 mm, 0.647 in. ~ 16.42 mm, 0.774 in. ~ 19.65 mm, 0.878 in. ~ 22.31 mm, 1.061 in. ~ 26.95 mm, 1.459 in. ~ 37.06 mm, 0.318 in. ~ 8.09 mm, 0.585 in. ~ 14.85 mm, 0.678 in. ~ 17.23 mm, 0.813 in. ~ 20.65 mm, 0.922 in. ~ 23.41 mm

CABLE WEIGHT

46 lbs/Mft ~ 69 kg/km, 108 lbs/Mft ~ 160 kg/km, 136 lbs/Mft ~ 202 kg/km, 167 lbs/Mft ~ 249 kg/km, 231 lbs/Mft ~ 344 kg/km, 320 lbs/Mft ~ 477 kg/km, 447 lbs/Mft ~ 665 kg/km, 803 lbs/Mft ~ 1195 kg/km, 58 lbs/Mft ~ 87 kg/km, 132 lbs/Mft ~ 196 kg/km, 212 lbs/Mft ~ 316 kg/km, 298 lbs/Mft ~ 444 kg/km, 410 lbs/Mft ~ 610 kg/km

MAX. PULLING TENSION

41 lbs ~ 19 kg, 83 lbs ~ 37 kg, 124 lbs ~ 56 kg, 165 lbs ~ 75 kg, 248 lbs ~ 112 kg, 330 lbs ~ 150 kg, 495 lbs ~ 225 kg, 991 lbs ~ 449 kg, 62 lbs ~ 28 kg, 124 lbs ~ 56 kg, 248 lbs ~ 112 kg, 372 lbs ~ 169 kg, 495 lbs ~ 225 kg

MIN. BEND RADIUS

4.9 in. ~ 124 mm, 8.9 in. ~ 227 mm, 9.5 in. ~ 240 mm, 10.3 in. ~ 263 mm, 12.4 in. ~ 314 mm, 14.1 in. ~ 357 mm, 21.2 in. ~ 539 mm, 29.2 in. ~ 741 mm, 5.1 in. ~ 129 mm, 9.4 in. ~ 238 mm, 10.9 in. ~ 278 mm, 13.0 in. ~ 330 mm, 14.7 in. ~ 375 mm

Related products

  • CIC Tray Cable 300V – Shielded Pairs & Triads 18 AWG

    $0.00
    Select options

NOTE: Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • Limited
    SMOKE

  • Halogen
    Free

  • TRAY
    CABLE (TC)

  • Exposed
    Run

  • DIRECT
    BURIAL

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */