Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > ACWU90 > Aluminum Conductors 600V > ACWU90 600V – 4 Aluminum Conductors

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

ACWU90 600V – 4 Aluminum Conductors

Conductor:

Stranded AA-8000 Series Aluminum Alloy (ACM)

Insulation:

Cross-linked Polyethylene (XLPE)

Colour Code:

Black with White Numbering or Colour Coded

Bonding Conductor:

Stranded AA-8000 Series Aluminum Alloy (ACM)

Armour:

Aluminum Interlock Armour (AIA)

Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

  • ACWU90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • CABLE
    TRAY

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 51, Armoured Cables
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 2556, FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

For wet and dry locations.

To be used for exposed and concealed wiring or where subject to the weather.

For direct earth burial and service entrance above or below ground.

Used in ventilated, non-ventilated and ladder-type cable trays.

Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

9190604, 9190404, 9190204, 9190104, 91901/004, 91902/004, 91903/004, 91904/004, 91925004, 91930004, 91935004, 91940004, 91950004, 91960004, 91975004

CONDUCTOR SIZE

6 AWG, 4 AWG, 2 AWG, 1 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 750 kcmil

BONDING CONDUCTOR SIZE

8 AWG, 6 AWG, 6 AWG, 4 AWG, 4 AWG, 4 AWG, 4 AWG, 4 AWG, 2 AWG, 2 AWG, 2 AWG, 2 AWG, 1 AWG, 1/0 AWG, 1/0 AWG

INSULATION THICKNESS

0.045 in. ~ 1.14 mm, 0.055 in. ~ 1.40 mm, 0.065 in. ~ 1.65 mm, 0.080 in. ~ 2.03 mm

ARMOUR O.D.

0.885 in. ~ 22.48 mm, 1.030 in. ~ 26.16 mm, 1.135 in. ~ 28.83 mm, 1.280 in. ~ 32.51 mm, 1.360 in. ~ 34.54 mm, 1.520 in. ~ 38.61 mm, 1.595 in. ~ 40.51 mm, 1.716 in. ~ 43.59 mm, 1.875 in. ~ 47.63 mm, 2.050 in. ~ 52.07 mm, 2.155 in. ~ 54.74 mm, 2.240 in. ~ 56.90 mm, 2.475 in. ~ 62.87 mm, 2.800 in. ~ 71.12 mm, 3.010 in. ~ 76.45 mm

CABLE O.D.

0.970 in. ~ 24.64 mm, 1.115 in. ~ 28.32 mm, 1.220 in. ~ 31.99 mm, 1.380 in. ~ 35.05 mm, 1.460 in. ~ 37.08 mm, 1.620 in. ~ 41.15 mm, 1.695 in. ~ 43.05 mm, 1.816 in. ~ 46.13 mm, 1.975 in. ~ 50.17 mm, 2.150 in. ~ 54.61 mm, 2.255 in. ~ 57.28 mm, 2.340 in. ~ 59.44 mm, 2.575 in. ~ 65.41 mm, 2.930 in. ~ 74.42 mm, 3.140 in. ~ 79.76 mm

CABLE WEIGHT

367 lbs/Mft ~ 546 kg/km, 486 lbs/Mft ~ 724 kg/km, 685 lbs/Mft ~ 1020 kg/km, 802 lbs/Mft ~ 1194 kg/km, 988 lbs/Mft ~ 1470 kg/km, 1002 lbs/Mft ~ 1492 kg/km, 1194 lbs/Mft ~ 1777 kg/km, 1619 lbs/Mft ~ 2410 kg/km, 1979 lbs/Mft ~ 2945 kg/km, 2282 lbs/Mft ~ 3397 kg/km, 2467 lbs/Mft ~ 3671 kg/km, 2516 lbs/Mft ~ 3744 kg/km, 3604 lbs/Mft ~ 5364 kg/km, 3970 lbs/Mft ~ 5908 kg/km, 4666 lbs/Mft ~ 6945 kg/km

MAX. PULLING TENSION

561 lbs ~ 225 kg, 888 lbs ~ 403 kg, 1410 lbs ~ 640 kg, 1763 lbs ~ 800 kg, 2220 lbs ~ 1007 kg, 2876 lbs ~ 1304 kg, 3600 lbs ~ 1633 kg, 4479 lbs ~ 2032 kg, 5496 lbs ~ 2493 kg, 6194 lbs ~ 2810 kg, 7889 lbs ~ 3578 kg, 8491 lbs ~ 3851 kg, 10457 lbs ~ 4743 kg, 12910 lbs ~ 5856 kg, 16606 lbs ~ 7532 kg

MID. BEND RADIUS

13.6 in. ~ 345 mm, 15.6 in. ~ 396 mm, 17.1 in. ~ 434 mm, 19.3 in. ~ 491 mm, 20.4 in. ~ 519 mm, 22.7 in. ~ 576 mm, 23.7 in. ~ 603 mm, 25.4 in. ~ 646 mm, 27.7 in. ~ 702 mm, 30.1 in. ~ 765 mm, 31.6 in. ~ 802 mm, 32.8 in. ~ 832 mm, 36.1 in. ~ 916 mm, 41.0 in. ~ 1042 mm, 44.0 in. ~ 1117 mm

AMPACITY (A)

44, 60, 80, 92, 108, 120, 140, 164, 184, 208, 224, 244, 280, 308, 348

Related products

  • ACWU90 600V – 1 Aluminum Conductor

    $0.00
    Select options
  • ACWU90 600V – 3 Aluminum Conductors

    $0.00
    Select options

NOTE: Ampacity values based on CEC Part I 2018, Table 4 and 5C. Correction factors may apply.

Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */