Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > RW90 > COPPER CONDUCTORS 1000V > RW90 1000V – 1 Copper Conductor

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

RW90 1000V – 1 Copper Conductor

Conductor:

Solid Soft Copper, ASTM B3

Stranded Bare Soft Copper, ASTM B8

Stranded Tinned Soft Copper, ASTM B8 and B33

Insulation:

Cross-linked Polyethylene (XLPE)

Jacket:

Optional Low Smoke Zero Halogen (LSZH) or Low Acid Gas (AG14) Polyvinyl Chloride (PVC)

  • RW90

  • LOW
    TEMP

  • HIGH
    TEMP

  • Halogen
    Free

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • Exposed
    Wiring

Specifications and Compliance:

  • CSA C22.2 No. 38 Thermoset-Insulated Wires and Cables Type RW90
  • -40°C Cold Bend and -40°C Cold Impact
  • SUN RES in all colours available upon request, HALOGEN-FREE

Applications:

For exposed wiring and raceways (except cable tray) in wet and dry locations.

Minimum recommended installation temperature of minus 40°C with proper handling procedures.

Cables marked SUN RES are also for outdoor use and exposed wiring subjected to the weather.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

81214, 81212, 81210, 81208, 81206, 81204, 81203, 81202, 81201, 81201/0, 81202/0, 81203/0, 81204/0, 812250, 812350, 812500, 812600, 812750, 8121000, 81314, 81312, 81310

CONDUCTOR SIZE

14/7 AWG, 12/7 AWG, 10/7 AWG, 8 AWG, 6 AWG, 4 AWG, 3 AWG, 2 AWG, 1 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 350 kcmil, 500 kcmil, 600 kcmil, 750 kcmil, 1000 kcmil, 14/1 AWG, 12/1 AWG, 10/1 AWG

CABLE O.D.

0.154 in. ~ 3.91 mm, 0.171 in. ~ 4.34 mm, 0.192 in. ~ 4.88 mm, 0.163 in. ~ 4.14 mm, 0.181 in. ~ 4.60 mm, 0.204 in. ~ 5.18 mm, 0.224 in. ~ 5.69 mm, 0.290 in. ~ 7.37 mm, 0.335 in. ~ 8.51 mm, 0.365 in. ~ 9.27 mm, 0.400 in. ~ 10.16 mm, 0.460 in. ~ 11.68 mm, 0.501 in. ~ 12.73 mm, 0.545 in. ~ 13.84 mm, 0.582 in. ~ 14.78 mm, 0.646 in. ~ 16.41 mm, 0.720 in. ~ 18.29 mm, 0.857 in. ~ 21.77 mm, 0.951 in. ~ 24.16 mm, 1.050 in. ~ 26.67 mm, 1.139 in. ~ 28.93 mm, 1.285 in. ~ 32.64 mm

CABLE WEIGHT

18 lbs/Mft ~ 27 kg/km, 26 lbs/Mft ~ 39 kg/km, 40 lbs/Mft ~ 60 kg/km, 20 lbs/Mft ~ 30 kg/km, 28 lbs/Mft ~ 42 kg/km, 42 lbs/Mft ~ 63 kg/km, 71 lbs/Mft ~ 106 kg/km, 102 lbs/Mft ~ 151 kg/km, 154 lbs/Mft ~ 230 kg/km, 191 lbs/Mft ~ 284 kg/km, 237 lbs/Mft ~ 346 kg/km, 310 lbs/Mft ~ 439 kg/km, 383 lbs/Mft ~ 521 kg/km, 484 lbs/Mft ~ 651 kg/km, 591 lbs/Mft ~ 809 kg/km, 738 lbs/Mft ~ 1006 kg/km, 899 lbs/Mft ~ 1250 kg/km, 1241 lbs/Mft ~ 1631 kg/km, 1748 lbs/Mft ~ 2459 kg/km, 2088 lbs/Mft ~ 3100 kg/km, 2594 lbs/Mft ~ 3608 kg/km, 3432 lbs/Mft ~ 4721 kg/km

MAX. PULLING TENSION

34 lbs ~ 15 kg, 52 lbs ~ 24 kg, 83 lbs ~ 38 kg, 151 lbs ~ 69 kg, 210 lbs ~ 95 kg, 334 lbs ~ 151 kg, 421 lbs ~ 191 kg, 531 lbs ~ 241 kg, 670 lbs ~ 304 kg, 844 lbs ~ 383 kg, 1065 lbs ~ 483 kg, 1343 lbs ~ 609 kg, 1692 lbs ~ 767 kg, 2000 lbs ~ 907 kg, 2802 lbs ~ 1271 kg, 3997 lbs ~ 1813 kg, 4802 lbs ~ 2178 kg, 6002 lbs ~ 2722 kg, 7995 lbs ~ 3627 kg, 34 lbs ~ 15 kg, 52 lbs ~ 24 kg, 83 lbs ~ 38 kg

AMPACITY (A)

25, 30, 40, 55, 75, 95, 115, 130, 145, 170, 195, 225, 260, 290, 380, 430, 475, 535, 615, 350

NOTE: NOTE: Ampacity values based on CEC Part I 2018, Table 2. Correction factors may apply.

Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • FLAME
    RATING

  • Limited
    SMOKE

  • TRAY
    CABLE (TC)

  • Exposed
    Run

  • DIRECT
    BURIAL

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */