Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > TECK90 Vertical Riser > Copper Conductors 1000V > V-TECK 1000V (Vertical Riser) – 3 Copper Conductors

ElectroPower®

 

CHECK INVENTORY
VIEW QUOTE

V-TECK 1000V (Vertical Riser) – 3 Copper Conductors

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE) Type RW90

Colour Code:

Solid Black, White and Red or Black with White Numbering

Bonding Conductor:

Stranded Soft Bare Copper, ASTM B8

Inner Jacket:

Ribbed Low Acid Gas Polyvinyl Chloride (PVC)

Armour:

Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour

Outer Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

  • Teck90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • CABLE
    TRAY

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 2556, FT4 Vertical-Tray Flame Test
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

Self-supporting cable designed for vertical runs with ribbed inner jacket and special armour design.

Typical applications include mine shafts, tall commercial and residential buildings and vertical raceways.

For direct earth burial and service entrance above or below ground.

Use in ventilated, non-ventilated and ladder-type cable trays.

Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.

To add or modify your quote request, please log in

  • Additional information

Additional information

PART NO.

T1XAAUS1/0-3C-V, T1XAAUS2/0-3C-V, T1XAAUS3/0-3C -V, T1XAAUS4/0-3C-V, T1XAAUS250-3C -V, T1XAAUS350-3C -V, T1XAAUS500-3C-V, T1XAAUS600-3C-V, T1XAAUS750-3C-V, T1XAAUS1000-3C-V

CONDUCTOR SIZE

1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 350 kcmil, 500 kcmil, 600 kcmil, 750 kcmil, 1000 kcmil

BONDING CONDUCTOR SIZE

6 AWG, 4 AWG, 3 AWG, 2 AWG, 1 AWG

INSULATION THICKNESS

0.080 in. ~ 2.03 mm, 0.090 in. ~ 2.29 mm

INNER JACKET O.D.

1.488 in. ~ 37.80 mm, 1.587 in. ~ 40.30 mm, 1.699 in. ~ 43.16 mm, 1.845 in. ~ 46.86 mm, 1.991 in. ~ 50.57 mm, 2.227 in. ~ 56.57 mm, 2.524 in. ~ 64.10 mm, 2.853 in. ~ 72.45 mm, 2.876 in. ~ 73.04 mm, 3.353 in. ~ 85.17 mm

ARMOUR O.D.

1.678 in. ~ 42.62 mm, 1.777 in. ~ 45.13 mm, 1.889 in. ~ 47.99 mm, 2.035 in. ~ 51.69 mm, 2.181 in. ~ 55.39 mm, 2.417 in. ~ 61.40 mm, 2.714 in. ~ 68.93 mm, 3.043 in. ~ 77.28 mm, 3.066 in. ~ 77.87 mm, 3.543 in. ~ 90.00 mm

CABLE O.D.

1.664 in. ~ 42.27 mm, 1.734 in. ~ 44.05 mm, 1.890 in. ~ 48.01 mm, 2.036 in. ~ 51.72 mm, 2.242 in. ~ 56.96 mm, 2.449 in. ~ 62.19 mm, 2.745 in. ~ 69.73 mm, 3.074 in. ~ 78.08 mm, 3.097 in. ~ 78.67 mm, 3.575 in. ~ 90.81 mm

CABLE WEIGHT

1785 lbs/Mft ~ 2655 kg/km, 2107 lbs/Mft ~ 3134 kg/km, 2469 lbs/Mft ~ 3673 kg/km, 3009 lbs/Mft ~ 4476 kg/km, 3560 lbs/Mft ~ 5296 kg/km, 4885 lbs/Mft ~ 7267 kg/km, 6702 lbs/Mft ~ 9969 kg/km, 7799 lbs/Mft ~ 11602 kg/km, 9356 lbs/Mft ~ 13917 kg/km, 12882 lbs/Mft ~ 19162 kg/km

MAX. PULLING TENSION

2807 lbs ~ 1273 kg, 3411 lbs ~ 1547 kg, 4213 lbs ~ 1911 kg, 5645 lbs ~ 2561 kg, 6869 lbs ~ 3116 kg, 11000 lbs ~ 4989 kg, 13249 lbs ~ 6010 kg, 15863 lbs ~ 7195 kg, 23904 lbs ~ 10843 kg, 31850 lbs ~ 14447 kg

MIN. BEND RADIUS

23.3 in. ~ 592 mm, 24.3 in. ~ 617 mm, 26.5 in. ~ 672 mm, 28.5 in. ~ 724 mm, 31.4 in. ~ 797 mm, 34.3 in. ~ 871 mm, 38.4 in. ~ 976 mm, 43.0 in. ~ 1093 mm, 43.4 in. ~ 1101 mm, 50.1 in. ~ 1271 mm

AMPACITY * AMPS

170, 195, 225, 260, 290, 350, 430, 475, 535, 615

Related products

  • V-TECK 1000V (Vertical Riser) – Copper Conductors – 1 Conductor

    $0.00
    Select options
  • V-TECK 1000V (Vertical Riser) – 4 Copper Conductors

    Read more
VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • Limited
    SMOKE

  • Halogen
    Free

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */