Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > TECK90 > Copper Conductors 1000V > TECK90 1000V – 2 Copper Conductors

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

TECK90 1000V – 2 Copper Conductors

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE)

Colour Code:

Black and White or Black with White Numbering

Bonding Conductor:

Stranded Soft Bare Copper, ASTM B8

Inner Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

Armour:

Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour

Outer Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

  • Teck90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • CABLE
    TRAY

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

For wet and dry locations.

To be used for exposed and concealed wiring or where subjected to the weather.

For direct earth burial and service entrance above or below ground.

Use in ventilated, non-ventilated and ladder-type cable trays.

Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

T1XAAUS14-2C, T1XAAUS12-2C, T1XAAUS10-2C, T1XAAUS8-2C, T1XAAUS6-2C, T1XAAUS4-2C, T1XAAUS3-2C, T1XAAUS2-2C, T1XAAUS1-2C, T1XAAUS1/0-2C, T1XAAUS2/0-2C, T1XAAUS3/0-2C, T1XAAUS4/0-2C, T1XAAUS250-2C, T1XAAUS350-2C, T1XAAUS500-2C

CONDUCTOR SIZE

14 AWG, 12 AWG, 10 AWG, 8 AWG, 6 AWG, 4 AWG, 3 AWG, 2 AWG, 1 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 350 kcmil, 500 kcmil

BONDING SIZE

14 AWG, 14 AWG, 12 AWG, 10 AWG, 8 AWG, 8 AWG, 6 AWG, 6 AWG, 6 AWG, 6 AWG, 6 AWG, 4 AWG, 4 AWG, 4 AWG, 3 AWG, 3 AWG

INSULATION THICKNESS

0.045 in. ~ 1.14 mm, 0.060 in. ~ 1.52 mm, 0.080 in. ~ 2.03 mm, 0.090 in. ~ 2.28 mm

INNER JACKET O.D.

0.390 in. ~ 9.91 mm, 0.415 in. ~ 10.54 mm, 0.435 in. ~ 11.05 mm, 0.515 in. ~ 13.08 mm, 0.680 in. ~ 17.27 mm, 0.775 in. ~ 19.69 mm, 0.910 in. ~ 23.11 mm, 0.955 in. ~ 24.26 mm, 1.145 in. ~ 29.08 mm, 1.200 in. ~ 30.48 mm, 1.295 in. ~ 32.89 mm, 1.390 in. ~ 35.31 mm, 1.475 in. ~ 37.47 mm, 1.605 in. ~ 40.77 mm, 1.905 in. ~ 48.39 mm, 2.155 in. ~ 54.74 mm

ARMOUR O.D.

0.630 in. ~ 16.0 mm, 0.655 in. ~ 16.6 mm, 0.675 in. ~ 17.1 mm, 0.755 in. ~ 19.2 mm, 0.920 in. ~ 23.4 mm, 1.015 in. ~ 25.8 mm, 1.150 in. ~ 29.2 mm, 1.195 in. ~ 30.4 mm, 1.385 in. ~ 35.2 mm, 1.440 in. ~ 36.6 mm, 1.535 in. ~ 39.0 mm, 1.630 in. ~ 41.4 mm, 1.715 in. ~ 43.6 mm, 1.845 in. ~ 46.9 mm, 2.145 in. ~ 54.5 mm, 2.395 in. ~ 60.8 mm

CABLE O.D.

0.715 in. ~ 18.2 mm, 0.735 in. ~ 18.7 mm, 0.760 in. ~ 19.3 mm, 0.840 in. ~ 21.3 mm, 1.005 in. ~ 25.5 mm, 1.135 in. ~ 28.8 mm, 1.235 in. ~ 31.4 mm, 1.280 in. ~ 32.5 mm, 1.470 in. ~ 37.3 mm, 1.525 in. ~ 38.7 mm, 1.620 in. ~ 41.1 mm, 1.735 in. ~ 44.1 mm, 1.820 in. ~ 46.2 mm, 1.950 in. ~ 49.5 mm, 2.245 in. ~ 57.0 mm, 2.525 in. ~ 64.1 mm

CABLE WEIGHT

227 lbs/Mft ~ 338 kg/km, 269 lbs/Mft ~ 401 kg/km, 283 lbs/Mft ~ 421 kg/km, 363 lbs/Mft ~ 540 kg/km, 470 lbs/Mft ~ 700 kg/km, 632 lbs/Mft ~ 941 kg/km, 826 lbs/Mft ~ 1230 kg/km, 880 lbs/Mft ~ 1310 kg/km, 1289 lbs/Mft ~ 1919 kg/km, 1441 lbs/Mft ~ 2145 kg/km, 1661 lbs/Mft ~ 2472 kg/km, 2026 lbs/Mft ~ 3015 kg/km, 2375 lbs/Mft ~ 3535 kg/km, 2802 lbs/Mft ~ 4170 kg/km, 3790 lbs/Mft ~ 5640 kg/km, 5046 lbs/Mft ~ 7510 kg/km

MAX. PULLING TENSION

66 lbs ~ 30 kg, 104 lbs ~ 47 kg, 166 lbs ~ 75 kg, 279 lbs ~ 126 kg, 468 lbs ~ 212 kg, 796 lbs ~ 361 kg, 1082 lbs ~ 491 kg, 1281 lbs ~ 581 kg, 1469 lbs ~ 666 kg, 1871 lbs ~ 849 kg, 2274 lbs ~ 1031 kg, 2809 lbs ~ 1274 kg, 3764 lbs ~ 1707 kg, 4580 lbs ~ 2077 kg, 7333 lbs ~ 3326 kg, 8833 lbs ~ 4006 kg

MIN. BEND RADIUS

10.0 in. ~ 254 mm, 10.3 in. ~ 261 mm, 10.6 in. ~ 270 mm, 11.8 in. ~ 299 mm, 14.1 in. ~ 357 mm, 15.9 in. ~ 404 mm, 17.3 in. ~ 439 mm, 17.9 in. ~ 455 mm, 20.6 in. ~ 523 mm, 21.5 in. ~ 542 mm, 22.7 in. ~ 576 mm, 24.3 in. ~ 617 mm, 25.5 in. ~ 647 mm, 27.3 in. ~ 693 mm, 31.4 in. ~ 798 mm, 35.4 in. ~ 898 mm

AMPACITY (A)

25, 30, 40, 55, 75, 95, 115, 130, 145, 170, 195, 225, 260, 290, 350, 430

Related products

  • TECK90 1000V – 3 Copper Conductors

    $0.00
    Select options
  • TECK90 1000V – 1 Copper Conductor

    $0.00
    Select options
  • TECK90 1000V – 4 Copper Conductors

    $0.00
    Select options

NOTE: Ampacity values based on CEC Part I 2018, Table 2. Correction factors may apply. Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • Limited
    SMOKE

  • Halogen
    Free

  • Steel Armour

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */