Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > TECK90 > Copper Conductors 600V > TECK90 600V – Copper Conductors – 10 AWG

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

TECK90 600V – Copper Conductors – 10 AWG

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE)

Colour Code:

Solid Black, White, Red & Blue or Black with White numbering

Bonding Conductor:

Stranded Soft Bare Copper, ASTM B8

Inner Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

Armour:

Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour

Outer Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

  • Teck90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • CABLE
    TRAY

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

For wet and dry locations.

To be used for exposed and concealed wiring or where subject to the weather.

For direct earth burial and service entrance above or below ground.

Used in ventilated, non-ventilated and ladder-type cable trays.

Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

T6XAAUS10-2C, T6XAAUS10-3C, T6XAAUS10-4C, T6XAAUS10-5C, T6XAAUS10-6C, T6XAAUS10-7C, T6XAAUS10-8C, T6XAAUS10-9C, T6XAAUS10-10C, T6XAAUS10-11C, T6XAAUS10-12C, T6XAAUS10-15C, T6XAAUS10-20C, T6XAAUS10-25C, T6XAAUS10-30C, T6XAAUS10-40C, T6XAAUS10-50C

CONDUCTOR COUNT

2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 20, 25, 30, 40, 50

BONDING CONDUCTOR SIZE

12 AWG

INSULATION THICKNESS

0.030 in. ~ 0.76 mm

INNER JACKET O.D.

0.400 in. ~ 10.16 mm, 0.430 in. ~ 10.92 mm, 0.500 in. ~ 12.70 mm, 0.555 in. ~ 14.10 mm, 0.640 in. ~ 16.26 mm, 0.655 in. ~ 16.64 mm, 0.660 in. ~ 16.76 mm, 0.750 in. ~ 19.05 mm, 0.770 in. ~ 19.56 mm, 0.790 in. ~ 20.07 mm, 0.820 in. ~ 20.83 mm, 0.845 in. ~ 21.46 mm, 1.050 in. ~ 26.67 mm, 1.176 in. ~ 29.87 mm, 1.240 in. ~ 31.50 mm, 1.455 in. ~ 36.96 mm, 1.610 in. ~ 40.89 mm

ARMOUR O.D.

0.640 in. ~ 16.3 mm, 0.670 in. ~ 17.0 mm, 0.740 in. ~ 18.8 mm, 0.795 in. ~ 20.2 mm, 0.880 in. ~ 22.4 mm, 0.895 in. ~ 22.7 mm, 0.900 in. ~ 22.9 mm, 0.990 in. ~ 25.1 mm, 1.010 in. ~ 25.7 mm, 1.030 in. ~ 26.2 mm, 1.060 in. ~ 26.9 mm, 1.085 in. ~ 27.6 mm, 1.290 in. ~ 32.8 mm, 1.416 in. ~ 36.0 mm, 1.480 in. ~ 37.6 mm, 1.695 in. ~ 43.1 mm, 1.850 in. ~ 47.0 mm

CABLE O.D.

0.725 in. ~ 18.4 mm, 0.755 in. ~ 19.1 mm, 0.825 in. ~ 21.0 mm, 0.880 in. ~ 22.4 mm, 0.964 in. ~ 24.5 mm, 0.980 in. ~ 24.9 mm, 0.985 in. ~ 25.0 mm, 1.075 in. ~ 27.3 mm, 1.094 in. ~ 27.8 mm, 1.114 in. ~ 28.3 mm, 1.144 in. ~ 29.1 mm, 1.170 in. ~ 29.7 mm, 1.380 in. ~ 35.1 mm, 1.500 in. ~ 38.1 mm, 1.590 in. ~ 40.4 mm, 1.800 in. ~ 45.7 mm, 1.955 in. ~ 49.7 mm

CABLE WEIGHT

282 lbs/Mft ~ 420 kg/km, 292 lbs/Mft ~ 435 kg/km, 370 lbs/Mft ~ 550 kg/km, 406 lbs/Mft ~ 605 kg/km, 512 lbs/Mft ~ 762 kg/km, 533 lbs/Mft ~ 793 kg/km, 688 lbs/Mft ~ 1024 kg/km, 705 lbs/Mft ~ 1050 kg/km, 746 lbs/Mft ~ 1110 kg/km, 764 lbs/Mft ~ 1137 kg/km, 880 lbs/Mft ~ 1310 kg/km, 1049 lbs/Mft ~ 1561 kg/km, 1312 lbs/Mft ~ 1953 kg/km, 1518 lbs/Mft ~ 2259 kg/km, 1758 lbs/Mft ~ 2617 kg/km, 2284 lbs/Mft ~ 3399 kg/km, 2698 lbs/Mft ~ 4015 kg/km

MAX. PULLING TENSION

166 lbs ~ 75 kg, 249 lbs ~ 113 kg, 332 lbs ~ 151 kg, 415 lbs ~ 188 kg, 498 lbs ~ 226 kg, 581 lbs ~ 264 kg, 665 lbs ~ 301 kg, 748 lbs ~ 339 kg, 831 lbs ~ 377 kg, 914 lbs ~ 414 kg, 997 lbs ~ 452 kg, 1246 lbs ~ 565 kg, 1661 lbs ~ 754 kg, 2077 lbs ~ 942 kg, 2492 lbs ~ 1130 kg, 3323 lbs ~ 1507 kg, 4153 lbs ~ 1884 kg

MIN. BEND RADIUS

10.2 in. ~ 258 mm, 10.6 in. ~ 269 mm, 11.6 in. ~ 293 mm, 12.3 in. ~ 313 mm, 13.5 in. ~ 343 mm, 13.7 in. ~ 349 mm, 13.8 in. ~ 350 mm, 15.1 in. ~ 382 mm, 15.3 in. ~ 389 mm, 15.6 in. ~ 396 mm, 16.0 in. ~ 407 mm, 16.4 in. ~ 416 mm, 19.3 in. ~ 491 mm, 21.0 in. ~ 533 mm, 22.3 in. ~ 565 mm, 25.2 in. ~ 640 mm, 27.4 in. ~ 695 mm

AMPACITY (A)

40, 40, 32, 32, 32, 28, 28, 28, 28, 28, 28, 28, 28, 24, 24, 24, 20

Related products

  • TECK90 600V – Copper Conductors – 12 AWG

    $0.00
    Select options
  • TECK90 600V – Copper Conductors – 14 AWG

    $0.00
    Select options

NOTE: Ampacity values based on CEC Part I 2018, Table 2 and 5C. Correction factors may apply. Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • Limited
    SMOKE

  • Halogen
    Free

  • Steel Armour

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */