Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > TECK90 > Copper Conductors 600V > TECK90 600V – Copper Conductors – 14 AWG

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

TECK90 600V – Copper Conductors – 14 AWG

Conductor:

Stranded Soft Bare Copper, ASTM B8

Insulation:

Cross-linked Polyethylene (XLPE)

Colour Code:

Black, White, Red & Blue or Black with White numbering

Bonding Conductor:

Stranded Soft Bare Copper, ASTM B8

Inner Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

Armour:

Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour

Outer Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

  • Teck90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • CABLE
    TRAY

  • Exposed
    Run

  • DIRECT
    BURIAL

  • Hazardous
    Location

Specifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 174, Cables and cable glands for use in hazardous locations
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

For wet and dry locations.

To be used for exposed and concealed wiring or where subject to the weather.

For direct earth burial and service entrance above or below ground.

Used in ventilated, non-ventilated and ladder-type cable trays.

Approved for all hazardous locations as per CEC Part 2018 Section 18, when installed with approved connectors.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

T6XAAUS14-2C, T6XAAUS14-3C, T6XAAUS14-4C, T6XAAUS14-5C, T6XAAUS14-6C, T6XAAUS14-7C, T6XAAUS14-8C, T6XAAUS14-9C, T6XAAUS14-10C, T6XAAUS14-11C, T6XAAUS14-12C, T6XAAUS14-15C, T6XAAUS14-20C, T6XAAUS14-25C, T6XAAUS14-30C, T6XAAUS14-40C, T6XAAUS14-50C

CONDUCTOR COUNT

2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 20, 25, 30, 40, 50

BONDING CONDUCTOR SIZE

14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG, 14 AWG

INSULATION THICKNESS

0.030 in. ~ 0.76 mm

INNER JACKET O.D.

0.320 in. ~ 8.13 mm, 0.355 in. ~ 9.02 mm, 0.380 in. ~ 9.65 mm, 0.400 in. ~ 10.16 mm, 0.445 in. ~ 11.30 mm, 0.500 in. ~ 12.70 mm, 0.520 in. ~ 13.21 mm, 0.560 in. ~ 14.22 mm, 0.600 in. ~ 15.24 mm, 0.615 in. ~ 15.62 mm, 0.640 in. ~ 16.26 mm, 0.715 in. ~ 18.16 mm, 0.840 in. ~ 21.34 mm, 0.880 in. ~ 22.35 mm, 1.025 in. ~ 26.04 mm, 1.200 in. ~ 30.48 mm, 1.240 in. ~ 31.50 mm

ARMOUR O.D.

0.560 in. ~ 14.2 mm, 0.595 in. ~ 15.1 mm, 0.620 in. ~ 15.7 mm, 0.640 in. ~ 16.3 mm, 0.685 in. ~ 17.4 mm, 0.740 in. ~ 18.8 mm, 0.760 in. ~ 19.3 mm, 0.800 in. ~ 20.3 mm, 0.840 in. ~ 21.3 mm, 0.855 in. ~ 21.7 mm, 0.880 in. ~ 22.4 mm, 0.955 in. ~ 24.3 mm, 1.080 in. ~ 27.4 mm, 1.120 in. ~ 28.4 mm, 1.265 in. ~ 32.1 mm, 1.440 in. ~ 36.6 mm, 1.480 in. ~ 37.6 mm

CABLE O.D.

0.645 in. ~ 16.4 mm, 0.680 in. ~ 17.3 mm, 0.705 in. ~ 17.9 mm, 0.725 in. ~ 18.4 mm, 0.770 in. ~ 19.6 mm, 0.825 in. ~ 21.0 mm, 0.845 in. ~ 21.5 mm, 0.885 in. ~ 22.5 mm, 0.925 in. ~ 23.5 mm, 0.940 in. ~ 23.9 mm, 0.965 in. ~ 24.5 mm, 1.040 in. ~ 26.4 mm, 1.165 in. ~ 29.6 mm, 1.205 in. ~ 30.6 mm, 1.350 in. ~ 34.3 mm, 1.524 in. ~ 38.7 mm, 1.560 in. ~ 39.6 mm

CABLE WEIGHT

207 lbs/Mft ~ 308 kg/km, 218 lbs/Mft ~ 325 kg/km, 225 lbs/Mft ~ 335 kg/km, 265 lbs/Mft ~ 394 kg/km, 308 lbs/Mft ~ 459 kg/km, 312 lbs/Mft ~ 464 kg/km, 421 lbs/Mft ~ 627 kg/km, 435 lbs/Mft ~ 647 kg/km, 443 lbs/Mft ~ 659 kg/km, 472 lbs/Mft ~ 703 kg/km, 499 lbs/Mft ~ 743 kg/km, 573 lbs/Mft ~ 853 kg/km, 750 lbs/Mft ~ 1116 kg/km, 869 lbs/Mft ~ 1294 kg/km, 989 lbs/Mft ~ 1472 kg/km, 1258 lbs/Mft ~ 1873 kg/km, 1378 lbs/Mft ~ 2051 kg/km

MAX. PULLING TENSION

66 lbs ~ 30 kg, 99 lbs ~ 45 kg, 131 lbs ~ 60 kg, 164 lbs ~ 75 kg, 197 lbs ~ 89 kg, 230 lbs ~ 104 kg, 263 lbs ~ 119 kg, 296 lbs ~ 134 kg, 329 lbs ~ 149 kg, 362 lbs ~ 164 kg, 394 lbs ~ 179 kg, 493 lbs ~ 224 kg, 657 lbs ~ 298 kg, 822 lbs ~ 373 kg, 986 lbs ~ 447 kg, 1315 lbs ~ 596 kg, 1644 lbs ~ 745 kg

MIN. BEND RADIUS

9.0 in. ~ 229 mm, 9.5 in. ~ 242 mm, 9.9 in. ~ 251 mm, 10.2 in. ~ 258 mm, 10.8 in. ~ 274 mm, 11.6 in. ~ 293 mm, 11.8 in. ~ 301 mm, 12.4 in. ~ 315 mm, 13.0 in. ~ 329 mm, 13.2 in. ~ 334 mm, 13.5 in. ~ 343 mm, 14.6 in. ~ 370 mm, 16.3 in. ~ 414 mm, 16.9 in. ~ 429 mm, 18.9 in. ~ 480 mm, 21.3 in. ~ 542 mm, 21.8 in. ~ 555 mm

AMPACITY (A)

25, 25, 20, 20, 20, 17, 17, 17, 17, 17, 17, 17, 17, 15, 15, 15, 12

Related products

  • TECK90 600V – Copper Conductors – 10 AWG

    $0.00
    Select options
  • TECK90 600V – Copper Conductors – 12 AWG

    $0.00
    Select options

NOTE: Ampacity values based on CEC Part I 2018, Table 2 and 5C. Correction factors may apply. Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • Limited
    SMOKE

  • Halogen
    Free

  • Steel Armour

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */