Electro Cables
Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact
Electro Cables

Have a question? Contact us at 1 (888) 353-2876

Login
  • Products
  • Custom Cable
  • Inventory
  • About
  • Careers
  • Contact

PRODUCTS

A partner you can trust

  

Browse Products

Building & Industrial

Component Cable

Electronic Cables

Category & Coaxial Cable

Transit & Railway Cable

Custom Cable

AC90▸

Copper Conductors 600V▸

Aluminum Conductors 600V▸

ACWU90▸

Aluminum Conductors 600V▸

Copper Conductors 600V▸

TECK90▸

Copper Conductors 600V▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

TECK90 Vertical Riser▸

Copper Conductors 1000V▸

Aluminum Conductors 1000V▸

Lighting Power & Control▸

Control & Instrumentation Cable▸

ACIC Shielded Pairs & Triads▸

ACIC ELCON® Non-Shielded Multi-Conductor▸

CIC TC Shielded Pairs & Triads▸

CIC TC Multi-Conductor▸

RW90▸

COPPER CONDUCTORS 600V▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 600V▸

RWU90▸

COPPER CONDUCTORS 1000V▸

ALUMINUM CONDUCTORS 1000V▸

Solar / Photovoltaic Cable▸

NMD90▸

NMWU90▸

TW75▸

TWU▸

Bare Wire▸

Fire Alarm▸

FAS FT4 CSA▸

ARMOURED▸

UNARMOURED▸

FPLR CMR UL▸

TEW FT1 CSA | AWM MTW VW1 UL▸

TR-64 FT1 CSA | AWM VW1 UL▸

Low Voltage Thermostat▸

Speaker Wire▸

Irrigation▸

Tracer▸

CMG AWM FT4 CSA | CMG UL▸

Unshielded▸

Overall Foil Shield▸

CMP FT6 CSA | CMP PLENUM UL▸

LOW CAPACITANCE CABLE▸

STATION Z / QUAD CABLE▸

Category 5e▸

Category 6▸

Category 6A▸

Traffic Signal▸

CP-100▸

MTOIMSACP-100ISO-SPC90 600VSPC90 600VTWU 600VTW75 600VCMP FT6 CSACMR RISER UL CMG FT4 CSA4 Conductor3 Conductor1 Conductor4 Conductor3 Conductor1 Conductor4 Conductor4 Conductor3 Conductor1 Conductor1 Conductor3 Conductor1 ConductorRPVU90 Copper 2000VRPVU90 Aluminum 2000VRPV90 Copper 600VRPV90 Copper 2000V16 AWGNMD90 Aluminum 300VNMD90 Copper 300VCMP FT6 CMG FT4 14, 12 and 10 AWG 600V SHIELDED14, 12 and 10 AWG 600V UNSHIELDED18 AWG 300V16 AWG 300V16 AWG 600V18 AWG14 AWG to 10 AWG20 AWG to 12 AWG300V Tinned Copper16 AWG & 18 AWG600V Bare Copper600V Tinned CopperIn-Wall and Parallel14 AWG & 12 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG12 AWG14 AWG16 AWG18 AWG10 AWGCAT6A F/UTP Shielded Armoured12 AWGCAT6 F/UTP Shielded Armoured14 AWGV-TECK 4 ConductorCAT5e U/UTP Unshielded ArmouredCAT5e F/UTP Shielded ArmouredV-TECK 3 Conductor4 Conductor3 Conductor2 Conductor1 ConductorV-TECK 4 ConductorV-TECK 3 Conductor4 Conductor3 Conductor1 ConductorBare Copper Wire4 Conductor3 Conductor1 ConductorSingle and Multi-conductorsISO-AC904 Conductor3 Conductor2 Conductor (Black/Red)2 Conductor (Black/White)4 Conductor3 ConductorCUSTOM CABLE16 AWG 600V18 AWG 600V16 AWG 300V18 AWG 300VNMWU90 300V20 AWG22 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG14 AWG16 AWG18 AWG20 AWG22 AWG24 AWG
Home > Shop > Building & Industrial > TECK90 > Aluminum Conductors 1000V > TECK90 1000V – 3 Aluminum Conductors

ElectroPower®

PRODUCT PDF
CHECK INVENTORY
VIEW QUOTE

TECK90 1000V – 3 Aluminum Conductors

Conductor:

Stranded AA-8000 Series Aluminum Alloy (ACM)

Insulation:

Cross-linked Polyethylene (XLPE)

Colour Code:

Black with White Numbering

Bonding Conductor:

Stranded Bare AA-8000 Series Aluminum Alloy (ACM)

Inner Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

Armour:

Aluminum Interlock Armour (AIA)

Outer Jacket:

Low Acid Gas Polyvinyl Chloride (PVC)

  • Teck90

  • FLAME
    RATING

  • LOW
    TEMP

  • HIGH
    TEMP

  • UV
    Resistant

  • WET
    LOCATION

  • Chemical
    Resistant

  • Oil
    Resistant

  • Impact
    Resistant

  • CABLE
    TRAY

  • Exposed
    Run

  • DIRECT
    BURIAL

Specifications and Compliance:

  • CSA C22.2 No. 131, Type TECK 90
  • CSA C22.2 No. 38, Thermoset-insulated wires and cables
  • CSA C22.2 No. 2556 FT4 Vertical-Tray Flame Test
  • -40°C Cold Bend and -40°C Cold Impact
  • Sunlight Resistant, SUN RES and Low Acid Gas, AG14

Applications:

For wet and dry locations.

To be used for exposed and concealed wiring or where subject to the weather.

For direct earth burial and service entrance above or below ground.

Used in ventilated, non-ventilated and ladder-type cable trays.

To add or modify your quote request, please log in

Available Options:

  • Additional information

Additional information

PART NO.

T1XAAUS4-3C-AL, T1XAAUS2-3C-AL, T1XAAUS1-3C-AL, T1XAAUS1/0-3C-AL, T1XAAUS2/0-3C-AL, T1XAAUS3/0-3C-AL, T1XAAUS4/0-3C-AL, T1XAAUS250-3C-AL, T1XAAUS350-3C-AL, T1XAAUS500-3C-AL, T1XAAUS750-3C-AL

CONDUCTOR SIZE

4 AWG, 2 AWG, 1 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 350 kcmil, 500 kcmil, 750 kcmil

BONDING CONDUCTOR SIZE

6 AWG, 4 AWG, 2 AWG, 1 AWG, 1/0 AWG

INSULATION THICKNESS

0.060 in. ~ 1.52 mm, 0.080 in. ~ 2.03 mm, 0.090 in. ~ 2.29 mm

INNER JACKET O.D.

0.881 in. ~ 22.38 mm, 1.002 in. ~ 25.46 mm, 1.168 in. ~ 29.66 mm, 1.249 in. ~ 31.72 mm, 1.258 in. ~ 31.95 mm, 1.342 in. ~ 34.08 mm, 1.559 in. ~ 39.59 mm, 1.758 in. ~ 44.64 mm, 1.969 in. ~ 50.01 mm, 2.233 in. ~ 56.73 mm, 2.603 in. ~ 66.11 mm

ARMOUR O.D.

1.140 in. ~ 28.96 mm, 1.270 in. ~ 32.26 mm, 1.400 in. ~ 35.56 mm, 1.450 in. ~ 36.83 mm, 1.560 in. ~ 39.62 mm, 1.670 in. ~ 42.42 mm, 1.825 in. ~ 46.36 mm, 1.985 in. ~ 50.42 mm, 2.219 in. ~ 56.36 mm, 2.500 in. ~ 63.50 mm, 2.796 in. ~ 71.02 mm

CABLE O.D.

1.220 in. ~ 30.99 mm, 1.341 in. ~ 34.07 mm, 1.507 in. ~ 38.27 mm, 1.604 in. ~ 40.74 mm, 1.613 in. ~ 40.97 mm, 1.697 in. ~ 43.10 mm, 1.969 in. ~ 50.01 mm, 2.168 in. ~ 55.05 mm, 2.409 in. ~ 61.19 mm, 2.673 in. ~ 67.90 mm, 3.043 in. ~ 77.28 mm

CABLE WEIGHT

633 lbs/Mft ~ 942 kg/km, 764 lbs/Mft ~ 1137 kg/km, 889 lbs/Mft ~ 1323 kg/km, 1079 lbs/Mft ~ 1606 kg/km, 1228 lbs/Mft ~ 1827 kg/km, 1058 lbs/Mft ~ 1575 kg/km, 1218 lbs/Mft ~ 1813 kg/km, 1935 lbs/Mft ~ 2880 kg/km, 2307 lbs/Mft ~ 3434 kg/km, 3159 lbs/Mft ~ 4702 kg/km, 3658 lbs/Mft ~ 5444 kg/km

MAX. PULLING TENSION

751 lbs ~ 341 kg, 1195 lbs ~ 542 kg, 1506 lbs ~ 683 kg, 1902 lbs ~ 863 kg, 2396 lbs ~ 1087 kg, 3022 lbs ~ 1371 kg, 3809 lbs ~ 1728 kg, 4500 lbs ~ 2041 kg, 6300 lbs ~ 2858 kg, 9000 lbs ~ 4083 kg, 13500 lbs ~ 6124 kg

MIN. BEND RADIUS

17.1 in. ~ 434 mm, 18.8 in. ~ 477 mm, 21.1 in. ~ 536 mm, 22.5 in. ~ 570 mm, 22.6 in. ~ 574 mm, 23.8 in. ~ 603 mm, 27.6 in. ~ 700 mm, 30.3 in. ~ 771 mm, 33.7 in. ~ 857 mm, 37.4 in. ~ 951 mm, 42.6 in. ~ 1082 mm

AMPACITY (A)

75, 100, 115, 135, 150, 175, 205, 230, 280, 350, 435

Related products

  • TECK90 1000V – 1 Aluminum Conductor

    $0.00
    Select options
  • TECK90 1000V – 4 Aluminum Conductors

    $0.00
    Select options

NOTE: Ampacity values based on CEC Part I 2018, Table 4. Correction factors may apply. Dimensions and weights are nominal and subject to change without notice.

VIEW QUOTE () ADD TO QUOTE

For specifications, please contact our sales team at 1-888-ELECTRO (613-394-4896) or sales@electrocables.com.

Options

This cable is also available with the following options. For more information, please contact sales@electrocables.com or call 1-888-353-2876.

  • FLAME
    RATING

  • Limited
    SMOKE

  • Halogen
    Free

X

Invalid user name or password

Register Now Forgot your password?

Products

Products

LEARN MORE

Products

Current Inventory

Current Inventory

LEARN MORE

Current Inventory

Custom Solutions

Custom Solutions

WE CAN HELP

Custom Solutions

LOOKING
FOR HELP?

We are here to help. You can contact us or create an account online to have access to special products, technical specifications and our new online quote tool.

GET IN TOUCH

ELECTRO CABLES

9 Riverside Drive
P.O. Box 276
Trenton, Ontario
CANADA K8V 5R5

N.A. Toll Free: 888-ELECTRO
(1-888-353-2876)

World: 613-394-4896

Fax: 613-394-4101

Email: sales@electrocables.com

We manufacture cables that are certified by the Canadian Standards Association (CSA), listed by Underwriters Laboratories and/or listed by Intertek (ETL).

Our quality management system is registered to ISO 9001: 2015. Our team is dedicated to consistently providing quality service and products to our customers.

 SCROLL UP

© 2023 ELECTRO CABLES • SITE BY SNAP 360•

/* Omit closing PHP tag at the end of PHP files to avoid "headers already sent" issues. */